FIBERGLASS SNOUT INSTALLATION  

 

(Refer to the reverse side, for sizes to specify)

  1. Drill equally spaced 7/16” holes through SNOUT flange.
  2. Align SNOUT over outlet pipe (so lower edge is at least ½ the pipe diameter below the lowest inside point of the pipe) and mark holes drilled in flange on to the catch basin wall.
    Drill ¾” diameter holes into catch basin walls (approximately 1” or deeper).
  3. Insert anchors into holes in catch basin holes, expand anchors to secure.
     Attach anti-siphon pipe and elbow (assure that elbow faces into center of catch basin)  together, then attach to SNOUT using PVC cement.
  4. Remove the pressure sensitive backing off the gasket and apply the gasket to SNOUT flange.
    Bolt SNOUT assembly to the catch basin wall using the supplied 3/8” bolts and
    washers. DO NOT OVER TIGHTEN!