FIBERGLASS SNOUT INSTALLATION
(Refer to the reverse side, for sizes to specify)
- Drill equally spaced 7/16” holes through SNOUT flange.
- Align SNOUT over outlet pipe (so lower edge is at least ½ the pipe diameter below the lowest inside point of the pipe) and mark holes drilled in flange on to the catch basin wall.
Drill ¾” diameter holes into catch basin walls (approximately 1” or deeper).
- Insert anchors into holes in catch basin holes, expand anchors to secure.
Attach anti-siphon pipe and elbow (assure that elbow faces into center of catch basin) together, then attach to SNOUT using PVC cement.
- Remove the pressure sensitive backing off the gasket and apply the gasket to SNOUT flange.
Bolt SNOUT assembly to the catch basin wall using the supplied 3/8” bolts and washers. DO NOT OVER TIGHTEN! | |